STEP 18
Run heavy gauge wire from remote control box to electric motor
terminals. Prepare wire ends for motor terminals with heat shrink tubes,
5/16” ring terminals, and rubber boots. Attach BLACK wire to terminal 1
on motor. Attach RED wire to terminal 2. Always hold base nut while
tightening top nut. At Battery, rst attach RED wire to (+) positive post.
Then attach BLACK wire to (-) negative post. Check power by activating
switch to open position and closed position. When done, make sure all
connections are secure and all wires are clear of sharp edges.
Figure 18
Note: Use dielectric grease
(packet included) at all
ellectrical connections.
DUAL POLE CONNECTOR
(USED IN SOME APPLICATIONS)
(M1)
(M2)
HEAVY GAGE WIRE