22
WIRING ADDITIONAL ELECTRIC HOPPER BOTTOMS
Figure 19
Note: Use dielectric grease
(packet included) at all
electrical connections.
WIRE SCHEMATIC
BATTERY
REMOTE
CONTROL
BOX 1
REMOTE
CONTROL
BOX 2
MOTOR
2
MOTOR
1
Bat (-) Black Bat (-) Black
(-) Black
Bat (+) Red
(+) Red
Red Motor 2
Black Motor 1
Dual Pole
Connection
Black Motor 1
Red Motor 2
From Control Box 1
40 AMP
Breaker
Aux
(-) Black
(+) Red
Bat (+)
Heavy Gauge Wire
Heavy Gauge Wire
Heavy Gauge Wire
ELECTRIC MOTOR OPERATING INSTRUCTIONS
NOTE: Electric hopper system is equipped with an automatic circuit
breaker. Holding switch until circuit breaker trips is TOO LONG. To reduce
unnecessary strain on components, always release switch before circuit
breaker trips.
Note: Remote will come pre-programmed from the factory. Remote control
boxes will come numbered to coincide with programmed modes of remote.
Refer to Command-5 owner’s manual or the remote programming video at
www.agricover.com/rolltarps/videos for re-programming and directions to
program multiple remotes and receivers.
1: CLOSING HOPPER FROM OPEN POSITION
Push switch to the CLOSED position and hold. Visually view hopper gate position
and release switch when hopper gate is fully closed.
2: OPENING HOPPER FROM CLOSED POSITION
Push switch to the OPEN position and hold. Visually view hopper gate position
and release switch when hopper gate is at desired location.